Skip to content

Free shipping on orders over $99.

8:30 to 5 ET(704) 555-0142
Not sure what you have? Send the part number(704) 555-0142
Vesda VESDA VLF-500-00-UL LaserFOCUS Aspirating Smoke Detector view 1

VESDA VLF-500-00-UL LaserFOCUS Aspirating Smoke Detector

Vesda
$258.43
In stock — 21 available
In stock · ready to ship
Ships today — order before 3:00 PM ET
Delivery in 3–5 business days
Ships from the USA — free shipping over $99
BrandVesda
SKUVLF-500-00-UL
TypeAspirating Smoke Detectors
Variants1

VLF-500-00-UL — UL-certified VESDA LaserFOCUS aspirating smoke detector for business-critical spaces up to 5,380 sq ft (500 m²), European language set with English display labels.

The detector continually draws air through sampling holes in a pipe network, filters it, and passes it into a laser detection chamber where light scattering reveals very small quantities of smoke. Status reaches the user on the Smoke Dial display and through three changeover relays or an optional interface card. The UL variant is documented against UL 268 7th edition, whose nuisance-alarm requirement changes how the Fire 1 threshold must be set — see the installation notes below. Behind the field service door, the 10-sector Instant Fault Finder converts the Smoke Dial into a numbered fault readout so the specific fault is known before a service call is placed.

Specifications

Order code VLF-500-00-UL — European language set, English display labels
Supply voltage 24 VDC nominal (18 to 30 VDC)
Power consumption at 24 VDC 9.8 W nominal, 11.7 W in alarm
Current consumption at 24 VDC 410 mA nominal, 490 mA in alarm
Dimensions (W x H x D) 10-1/16 in x 7-1/5 in x 3-2/3 in (256 mm x 183 mm x 92 mm)
Weight Approx. 4.4 lb (2 kg)
IP rating IP30
Mounting Upright, inverted or horizontal with appropriate mounting bracket
Operating conditions Detector ambient 32°F to 103°F (0°C to 39°C); tested to (EN 54-20) 14°F to 131°F (-10°C to 55°C); sampled air -4°F to 140°F (-20°C to 60°C); humidity 5% to 95%, non-condensing
Area covered 5,380 sq ft (500 m²)
Air inlet pipe IPS 3/4 in (OD 1.05 in) or OD 25 mm (ID 21 mm); alternate pipe sizes can be modelled with ASPIRE
Single pipe length 150 ft (50 m) max — 5 to 8 sampling holes pre-engineered, 9 to 24 holes modelled with ASPIRE
Two-branch pipe length 90 ft (30 m) max per branch — 3 to 6 holes per branch pre-engineered, 7 to 12 modelled with ASPIRE
Return air sampling (U-shaped, per branch) 8 to 14 holes pre-engineered, 9 to 24 modelled with ASPIRE
Field wiring access 3 x 25 mm (1 in) cable entries, one rear entry
Terminals 30 to 12 AWG (0.2 mm² to 2.5 mm²)
Interfaces Power in/out; Fire 1, Action and Fault changeover relays each rated 2 A at 30 VDC; general purpose input (clean contact); external display port with power limited output; RS232 programming port
Alarm ranges Alert and Action 0.008 to 0.625% obs/ft (0.025 to 2.0% obs/m); Fire 1 and Fire 2 0.008 to 6.25% obs/ft (0.025 to 20% obs/m)
Alarm delays and threshold sets 0 to 60 seconds individually; two threshold sets, day and night
Display 4 alarm state indicators; fault and disabled indicators; 10-sector smoke level indicator; 10-sector Instant Fault Finder; reset, disable and test controls; smoke and flow AutoLearn controls and indicators
Event log Up to 18,000 events with date and time stamp — smoke trend, flow trend, fault, configuration and operational events
AutoLearn smoke and flow Minimum 15 minutes, maximum 15 days, default 14 days
Laser safety Class 1 laser product
Product certifications UL, CSFM, FDA, CE, FCC, RCM

Installation notes

  • UL 268 7th edition changes threshold design: the standard adds a nuisance alarm requirement, so at every sampling port the Fire 1 threshold must sit above the nuisance smoke level and below the smoke alarm level. The pipework must be analysed so a single detector threshold satisfies both criteria at every port. Alert, Action and Fire 2 are not subject to that requirement.
  • AutoLearn Smoke is disabled in UL 268 Ed7 Open Area mode because it may calculate sensitivities that exceed the standard's nuisance smoke limit. Plan on a designed threshold, not a learned one, in that mode.
  • Pre-engineered designs stop early: a single pipe is pre-engineered only to 8 holes and a branch to 6 per branch. Anything beyond that must be modelled in ASPIRE.
  • Return air grille sampling: recommended coverage is 4 sq ft (0.4 m²) per sampling hole, and holes should be rotated roughly 45° away from the incoming airflow and toward the grille surface to reduce the risk of a Low Flow Fault when the air handling unit stops.
  • Approvals differ from the non-UL VLF-500, whose data sheet lists ULC, FM, LPCB, VdS, VNIIPO, AFNOR, ActivFire and EN 54-20 classification. Do not carry those claims onto the UL variant.
  • Consumables: filter cartridge VSP-005; the aspirator for the VLF-500-UL is VSP-715, not the VLF-250's VSP-722.

Related models

  • VLF-500-02-UL — the same UL detector with international display labels and the English plus Asian language set.
  • VLF-500-00 — the non-UL VLF-500, same hardware envelope but a different approvals set including EN 54-20 classification.
  • VLF-250-00 — smaller LaserFOCUS rated to 250 m² with a 25 m pipe and 12 holes.
  • VIC-010 / VIC-020 / VIC-030 — VESDAnet Interface Card and Multifunction Control Cards for the VLF range.

Specifications taken from the Xtralis (Honeywell) "VESDA VLF-500-UL Product Guide," document 36286_A2, part number AD36286-001 (August 2021). Manufacturer specifications are subject to change without notice.

Documents

FAQ

What area does the VLF-500-UL cover?
Up to 5,380 sq ft (500 m²), depending on local codes and standards.

How does it report to the fire alarm panel?
Through three changeover relays (Fire 1, Action and Fault) rated 2 A at 30 VDC, or through optional VIC-010 VESDAnet Interface Card and VIC-020/VIC-030 Multifunction Control Cards.

Does it need software to commission?
No. Xtralis states the VLF can be installed and commissioned out of the box without a special interface or software programming tool.

Which spare parts does it use?
The filter cartridge is VSP-005 and the aspirator for the VLF-500-UL is VSP-715.

Questions about this product

Is VESDA VLF-500-00-UL LaserFOCUS Aspirating Smoke Detector in stock?

Yes — 21 units are available and ready to ship from our US warehouse.

How fast will VESDA VLF-500-00-UL LaserFOCUS Aspirating Smoke Detector ship?

Orders placed before 3:00 PM ET ship the same business day. Delivery takes 3–5 business days inside the USA.

Where does VESDA VLF-500-00-UL LaserFOCUS Aspirating Smoke Detector ship from?

It ships from the United States. Standard delivery is 3–5 business days, and orders placed before 3:00 PM ET go out the same day.

Cart0
Your cart is empty

Have an account? Log in to check out faster.

Continue shopping