Skip to content

Free shipping on orders over $99.

8:30 to 5 ET(704) 555-0142
Not sure what you have? Send the part number(704) 555-0142
Vesda VESDA VEA-040-A10-UL ASD with 3.5" Display view 1

VESDA VEA-040-A10-UL ASD with 3.5" Display

Vesda
$876.41
In stock — 41 available
In stock · ready to ship
Ships today — order before 3:00 PM ET
Delivery in 3–5 business days
Ships from the USA — free shipping over $99
BrandVesda
SKUVEA-040-A10-UL
TypeAspirating Smoke Detectors
Variants1

VEA-040-A10-UL — UL certified VESDA-E VEA-40 addressable aspirating smoke detector with 40 microbore sampling points and a 3.5 in colour touch screen.

The VEA is the pinpoint-addressable member of the VESDA-E family. Instead of one pipe network reporting a single zone, it runs 40 individually addressed microbore tubes, each terminating in its own sampling point. The detector draws a combined sample from every point, filters it and analyses it in the laser detection chambers of the smoke sensor module; once a Fire 1 alarm is raised, a rotary valve sequentially scans the sampling locations to identify which one or more carry the event. If the system is in pre-alarm, a technician can trigger a smoke scan of all locations to investigate before an alarm confirms. A vacuum pump drives the network, giving usable detection times over long tube runs, and airflow monitoring detects breakage or blockage of individual points and tubes at set intervals. That combination suits spaces where knowing exactly where the fire is matters — healthcare, prisons, education, retail and electrical cabinets — and it allows testing and maintenance to be centralised at the detector rather than done room by room.

Specifications

Order code VEA-040-A10-UL — VESDA-E VEA-040-A10-UL aspirating smoke detector with 3.5 in display
Sampling points 40 addressable microbore tubes with individual sampling points
Supply voltage 18 to 30 VDC (24 VDC nominal)
Maximum power 25.6 W quiescent, 36.9 W alarm
Power consumption at 24 VDC (40 tubes) 24.0 W quiescent, 36.9 W alarm; add 0.2 W with Ethernet enabled and 0.5 W with WiFi enabled
Peak current 3.5 A
Dimensions (W x H x D) 13.9 in x 13.2 in x 5.33 in (352 mm x 336 mm x 135.5 mm)
Weight 22.2 lb (10 kg)
Operating conditions Ambient 32°F to 102°F (0°C to 39°C); sampled air 32°F to 122°F (0°C to 50°C); tested to 32°F to 102°F (0°C to 39°C); humidity 5% to 95% RH, non-condensing
Storage conditions Humidity dry (<95%); temperature 0°C to 85°C; must not be exposed to sunlight or other radiation sources
Microbore tube size Outer diameter 6 mm, inner diameter 4 mm — metric tubes only
Microbore tube length Up to 164 ft (50 m) per tube in Open Area; up to 328 ft (100 m) per tube in Special Application
Flow monitoring Single tube blockage and breakage detection
Detection chamber sensitivity 0.020%/m to 16%/m (0.006%/ft to 4.88%/ft)
Fire 1 thresholds at the sampling point Standard 8.0%/m (2.5%/ft); Enhanced 4.0%/m (1.3%/ft); High 1.6%/m (0.5%/ft)
Relays 7 programmable relays, contacts rated 2 A at 30 VDC (resistive), programmable to latch or not latch
General purpose inputs Two GPIs, one monitored and one unmonitored
IP rating IP40 (not UL tested)
Mounting Upright on a solid surface, with the steel support bracket or directly to the mounting surface
Cable access 4 x 1 in (25 mm) cable entry ports
Cable termination Screw terminal blocks 0.2 to 2.5 mm² (24 to 14 AWG); use 18 AWG (1.1 mm²) or larger for power connections
Interfaces USB (Type 2), Ethernet (RJ45), WiFi 802.11 b/g/n, VESDAnet
Event log Up to 20,000 events on a FIFO basis with time and date stamp
Alarm and fault levels Four alarm levels (Alert, Action, Fire 1, Fire 2); two fault warning levels (Maintenance and Major Fault)
Field replaceable parts Filter, smoke sensor module, pump and rotary valve
Product certifications UL, CSFM, FDA, FCC

Installation notes

  • Fire 1 relay wiring to the panel is mandatory: the product guide requires the Fire 1 relay to be connected to the FACP for primary alarm reporting. Ethernet and WiFi are for configuration and secondary monitoring only, never the primary path.
  • Metric tube only: the sampling network uses 6 mm OD / 4 mm ID microbore tube. Imperial tube will not fit correctly — this is called out explicitly in the specification table.
  • Tube length depends on application class: 50 m per tube in Open Area, but 100 m per tube in Special Application. Designing to the 100 m figure in an open-area installation over-runs the certification.
  • Power wiring is sized separately from signal wiring: terminals accept 24 to 14 AWG, but power connections require 18 AWG (1.1 mm²) or larger. A 3.5 A peak during scan mode is what drives that.
  • Scanning happens after Fire 1: location identification runs once Fire 1 is raised. Before that, a manual smoke scan of all locations can be initiated from pre-alarm — the detector does not continuously address each point.
  • IP40 is stated but not UL tested.
  • Sampling point part numbers are in a separate document — the guide refers to data sheet document 29730 for sampling points, microbore tube and tube accessories.

Related models

  • VEA-040-A00 — the same 40-point detector with an LED fascia instead of the 3.5 in display.
  • VEA-040-A10 — the non-UL 3.5 in display model; its data sheet publishes different figures (27 W quiescent and alarm, up to 100 m per tube without an application-class split) and a different approvals set including ULC and EN 54-20.
  • VER-A40-40-STX — VESDA-E VEA 40-Relay Local StaX, used to identify and signal fire source locations on a fire panel loop.
  • VSP-972 / VSP-971 / VSP-973 / VSP-974 — VEA filter, smoke sensor module, pump and rotary valve spares.

Specifications taken from the Xtralis (Honeywell) "VESDA-E VEA-040-A10-UL Product Guide," document 36401_A1, part number AD36401-000 (April 2021). Manufacturer specifications are subject to change without notice.

Documents

FAQ

How many sampling points does it support?
40 addressable microbore tubes, each ending in its own sampling point.

What tubing does it use?
Metric microbore tube, 6 mm outer and 4 mm inner diameter. The guide notes that imperial tubes will not fit correctly.

Can Ethernet or WiFi be the primary alarm path?
No. The Fire 1 relay must be wired to the fire alarm control panel for primary alarm reporting; Ethernet and WiFi are for configuration and secondary monitoring.

How long can each tube be?
Up to 164 ft (50 m) per tube for Open Area and up to 328 ft (100 m) per tube for Special Application.

Questions about this product

Is VESDA VEA-040-A10-UL ASD with 3.5" Display in stock?

Yes — 41 units are available and ready to ship from our US warehouse.

How fast will VESDA VEA-040-A10-UL ASD with 3.5" Display ship?

Orders placed before 3:00 PM ET ship the same business day. Delivery takes 3–5 business days inside the USA.

Where does VESDA VEA-040-A10-UL ASD with 3.5" Display ship from?

It ships from the United States. Standard delivery is 3–5 business days, and orders placed before 3:00 PM ET go out the same day.

Cart0
Your cart is empty

Have an account? Log in to check out faster.

Continue shopping