Notifier NC-100 Addressable Control Module
| Brand | Notifier |
|---|---|
| SKU | NC-100 |
| Type | Control Modules |
| Variants | 1 |
Notifier NC-100 — addressable control module for Notifier FireWarden Series intelligent control panels, with one supervised Class B (Style Y) or Class A (Style Z) notification appliance circuit.
The NC-100 switches 24 VDC power from an external supply to horns, strobes and other notification appliances, so they can be activated manually or by panel programming on a zone or area basis. On command it disconnects supervision and connects the external supply in the correct polarity; the supply stays relay-isolated from the SLC, so a trouble on it cannot affect the loop.
Specifications
| Operating voltage | 15 to 32 VDC |
| SLC current | 350 µA average (LED flashing), 6.5 mA maximum (LED on) |
| External supply | 80 V RMS or DC maximum; 2 mA maximum drain |
| EOL resistor | 47K ohms |
| Addressing | Rotary switches, 01–99 on FireWarden-100-2, 01–50 on FireWarden-50 |
| Temperature | 32°F to 120°F (0°C to 49°C), 10% to 93% RH |
| Dimensions | 4.5 in. H x 4 in. W x 1.25 in. D |
| Mounting | 4 in. square x 2-1/8 in. deep box, or SMB500 surface box |
Installation notes
- The CB500 barrier is required by UL to separate power-limited and non-power-limited wiring in the same box.
- Contact rating examples: 3 A at 30 VDC resistive non-coded, 2 A at 30 VDC resistive coded.
- The LED blinks on each poll and turns on steady when the module is activated.
Related models
- NC-100R — relay module version (now on DN-60383).
- NMM-100 — monitor module for the same panels.
Documents
FAQ
Which panels is the NC-100 for?
Notifier FireWarden Series intelligent control panels: addresses 01–99 on the FireWarden-100-2 and 01–50 on the FireWarden-50.
Does it power the horns and strobes?
No. It switches 24 VDC power from a separate supply onto the notification circuit; the supply is relay-isolated from the SLC.
Can the circuit be wired Class A?
Yes. The NC-100 supports one Class B (Style Y) or Class A (Style Z) notification appliance circuit.
Is a barrier needed?
Yes, when power-limited and non-power-limited wiring share the same junction box: UL requires the CB500 control module barrier.
Questions about this product
Is Notifier NC-100 Addressable Control Module in stock?
Yes — 3 units are available and ready to ship from our US warehouse.
How fast will Notifier NC-100 Addressable Control Module ship?
Orders placed before 3:00 PM ET ship the same business day. Delivery takes 3–5 business days inside the USA.
Where does Notifier NC-100 Addressable Control Module ship from?
It ships from the United States. Standard delivery is 3–5 business days, and orders placed before 3:00 PM ET go out the same day.