Modulaser Kidde Fire Systems ModuLaser 9-30783-KID-ULF Aspirating Smoke Detector Module, UL 268/ULC-S529/FM, 24 VDC view

Kidde Fire Systems ModuLaser 9-30783-KID-ULF Aspirating Smoke Detector Module, UL 268/ULC-S529/FM, 24 VDC

Modulaser
$112.14
In stock — 4 available
In stock · ready to ship
Ships today — order before 3:00 PM ET
Delivery in 3–5 business days
Ships from the USA — free shipping over $99
BrandModulaser
SKU9-30783-KID-ULF
TypeAspirating Smoke Detectors
Variants1

9-30783-KID-ULF is the Kidde ModuLaser detector module, the self-contained aspirating unit of the ModuLaser modular aspirating smoke detection system. Each detector module draws air from its own sampling pipe zone, analyzes it with laser light scattering and ClassiFire artificial intelligence, and drives local relays for pre-alarm, alarm and fault. It reports to a separately ordered display module over RS-485 (SenseNET+); a Minimum or Standard display module supports up to 8 detector modules in a cluster.

Specifications

Operating voltage 24 VDC nominal (18.0 to 30.0 V)
Current at 24 VDC 218 mA (fan speed 1); 330 mA (fan speed 6, default); 762 mA (fan speed 16)
Detection principle Laser light scattering mass detection and particle evaluation
Particle sensitivity range 0.003 to 10 microns
Sensitivity range 0.00914 to 7.62 %obs/ft (0.03 to 25 %obs/m)
Alarm levels 4 (Aux, Pre-alarm, Alarm, Alarm 2)
Sampling pipe Up to 820 ft (250 m) combined; up to 50 sampling holes (design with PipeCAD)
Inlet / exhaust 1.06 or 0.98 in. (27 or 25 mm) OD; top or bottom; one inlet per module
Inputs 2 supervised, 15 kΩ 5% 1/4 W termination, programmable
Outputs 3 voltage-free relays, 2 A at 30 VDC, NO/NC/C, programmable
Event log 20,000 events per module
Connectivity RS-485 (SenseNET+), USB Type A and Type B, Ethernet
Dimensions (W x D x H) 4.35 x 5.25 x 11.8 in. (110.5 x 133.5 x 300 mm)
Weight 3.46 lb (1.57 kg)
Mounting 19 in. rack, DIN rail or surface; vertical orientation
Operating temperature 0 to 38 °C (UL/ULC); 0 to 49 °C (FM)
Humidity / rating 0 to 90% noncondensing; indoor, IP40
Certification FM, UL 268 7th edition, UL 268A, CSFM, ULC S529 (4th edition)

Compatibility and installation notes

  • Requires a display module, ordered separately: 9-30780-KID-ULF, 9-30781-KID-ULF (Standard) or 9-30782-KID-ULF (Command). A Command display module cannot replace a Minimum or Standard module within a cluster.
  • Listed for open area protection and special application under UL 268 and for duct detection under UL 268A, with duct airflow up to 4,000 ft/min.
  • Spare parts listed: 9-30791-2 detector cover, 9-30797 accessory kit, 9-30794 grommets, 9-30795 and 9-30796 pipe adapters, 9-30798-2 wiring housing, 9-30699N-P filter pack (6).

Documents

Specifications from Kidde data sheet K85001-1040, ModuLaser Detector Module, Issue 1.1 (12-16-25). Manufacturer specifications are subject to change.

Questions about this product

Is Kidde Fire Systems ModuLaser 9-30783-KID-ULF Aspirating Smoke Detector Module, UL 268/ULC-S529/FM, 24 VDC in stock?

Yes — 4 units are available and ready to ship from our US warehouse.

How fast will Kidde Fire Systems ModuLaser 9-30783-KID-ULF Aspirating Smoke Detector Module, UL 268/ULC-S529/FM, 24 VDC ship?

Orders placed before 3:00 PM ET ship the same business day. Delivery takes 3–5 business days inside the USA.

Where does Kidde Fire Systems ModuLaser 9-30783-KID-ULF Aspirating Smoke Detector Module, UL 268/ULC-S529/FM, 24 VDC ship from?

It ships from the United States. Standard delivery is 3–5 business days, and orders placed before 3:00 PM ET go out the same day.

Cart0
Your cart is empty

Have an account? Log in to check out faster.

Continue shopping